top of page

CBRN Gas Mask Filter NBC-77 SOF 40mm Thread - 20 Year Shelf Life

SKU NBC77SOF
Precio

$79.99

The NBC-77 SOF 40mm Gas Mask Filter Canister: A Comprehensive Protection Solution

The NBC-77 SOF 40mm gas mask filter canister, when used in conjunction with a full-face mask, mouthpiece assembly, or Powered Air-Purifying Respirator (PAPR), offers reliable protection for air passages against a broad spectrum of harmful and highly toxic substances, including all known Chemical, Biological, Radiological, and Nuclear (CBRN) agents. This makes it an essential component for individuals operating in environments with a high risk of exposure to these hazardous substances.

 

Key Features and Benefits:

  • Wide Range of Protection: The NBC-77 SOF filter is designed to provide comprehensive protection against various harmful substances. This includes chemical warfare agents (such as nerve agents, blister agents, and blood agents), biological threats (such as bacteria, viruses, and spores), radiological particles, and nuclear fallout. The filter ensures that users are safeguarded against these threats, enabling them to operate safely in contaminated environments.

  • Standardized Compatibility: The filters are produced with standard round threads according to STANAG 4155 (EN 148-1) – Rd 40x1/7". This standardization ensures compatibility with various masks and breathing apparatuses that utilize the 40mm thread format. As a result, users can integrate the NBC-77 SOF filter with existing equipment seamlessly, making it a versatile and adaptable solution for various operational needs.

  • Robust and Durable Construction: The filter components are made of hard plastic, contributing to a robust product that is exceptionally durable against shock and impact damage during operational use. This rugged construction ensures that the filters can withstand the rigors of demanding environments, maintaining their integrity and performance even under harsh conditions.

  • Operational Reliability: The NBC-77 SOF filter canister is designed to perform reliably in diverse operational scenarios. Whether used by military personnel, first responders, or industrial workers, the filter's ability to provide consistent and dependable protection is crucial for mission success and safety.

  • Ease of Use and Maintenance: The NBC-77 SOF filter's standardized design and durable materials not only make it easy to use but also simplify maintenance and replacement procedures. This ensures that users can focus on their tasks without worrying about complex or time-consuming equipment management.

 

Applications:

The NBC-77 SOF 40mm gas mask filter canister is suitable for a wide range of applications, including:

  • Military Operations: Providing essential protection for soldiers in CBRN threat environments.
  • Emergency Response: Ensuring the safety of first responders during chemical spills, biological threats, or radiological incidents.
  • Industrial Safety: Protecting workers in industries where exposure to toxic substances is a concern.
  • Disaster Management: Offering protection during nuclear or radiological emergencies.

 

The NBC-77 SOF 40mm gas mask filter canister stands out as a critical component in the realm of CBRN protection. Its comprehensive protective capabilities, standardized compatibility, robust construction, and operational reliability make it an invaluable asset for anyone facing the threat of exposure to harmful and highly toxic substances.

 

Whether in military, emergency response, industrial, or disaster management scenarios, the NBC-77 SOF filter ensures that users can perform their duties safely and effectively, with confidence in their protective equipment.

Cantidad

NBC-77 SOF GAS MASK FILTER KEY FEATURES:

  • Compatible with standard 40mm NATO threaded respirators, which are widely available.
  • 20-year shelf life - save money long-term by not having to replace your filters every 5 years
  • Used by military personnel, CBRN specialists, and special operations forces all over the world
  • Filter all known CBRN agents, including radioactive iodine, rated for A2B2E2K2HgSXP3 D R.
  • Certified by European agencies and has the “CE” symbol. Compliant under EN 14387:2004 + A1:2008

TECHNICAL DATA

BREATHING RESISTANCE IN PA

Diameter110 mm@ flow rate 30l/min.

EN 1) NBC-77 SOF 260 <140@ flow rate 95l/min.

EN 1) NBC-77 SOF 980 <600Height85 mmWeight335 g ±5%

Storage time  20 years (factory sealed)

TYPE AND CLASS PARTICLE FILTER EFFICIENCY

A2 - organic gases and vapors SX - CG, CK, PS Sodium Chloride NaCl (S) Paraffin oil (L) EN 99.95 99.95 NBC-77 SOF >99.999 >99.999
B2 - inorganic gases and vapors P3 - particles
E2 - acid gases and vapors D- dust
K2 - ammonia and amines R- reusable
Hg - mercury vapors REACTOR - radioactive iodine

NBC-77 SOF GAS MASK FILTER APPLICATION:

The filter canister in connection with a suitable respirator or PAPR provides protection against solid and liquid particles, pepper spray (OC), smoke-producing substances, radioactive particles, bacteria and rickettsia, fungi, toxins, viruses, riot control agents (lachrymators, sternutators, vomiting agents), blister agents (vesicants), choking agents, blood agents, nerve agents, incapacitants, herbicides, pesticides, and TIC, such as bromoacetone, CS, CR, CN, CNC, CNS, CA substances, organic compounds of arsenic - diphenyldichlorarsine - CLARK I (DA), diphenylcyanoarsine - CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulphur mustard gas (HD), T-mustard gas, Q-mustard gas, nitrogen mustard gases (HN1, HN2, HN3), lewisite (L), mixed mustard gas (H-L), phosgene oxime (CX), phosgene (CG), diphosgene(DP), chloropicrin (PS), hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA), G-agents: sarin (GB), cyclosarin (GF), soman (GD), tabun (GA), IVA (GV), V-agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: fumes of organic or inorganic acids, hydroxides, organic solvents with a boiling point above 65° C, ammonia, amines, inorganic and acid gases, agricultural chemical combustion gases, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, chloroacetic acid, aldehydes, mixtures of inorganic acids, and organic substances, mercury vapors, radioactive iodine, organic compounds of iodine (Iodomethane, 129, 131), radioactive particles, etc.

TESTING GAS CONCENTRATION OF TESTING GAS BREAKTHROUGH TIME IN MINUTES EN NBC-77 SOF DAC IN GRAMS NBC-77 SOF
PPM MG/I
A2 Cyclohexane C₆H₁₂ 5000 17.5 35 39 20.475
B2 Chlorine Cl₂ 5000 15 20 45 20.250
  Hydrogen Sulphide H₂S 5000 7.1 40 >80 >17.400
  Hydrogen Cyanide HCN 5000 5.6 25 50 8.400
E2 Sulphur Dioxide SO₂ 5000 13.3 20 25 9.975
K2 Ammonia NH₃ 5000 3.5 40 50 5.250
Hg Mercury Hg ----- 13 mg/m³ 100 hours >170 hours >3.900
SX Cyanogen chloride CICN 2500 6.28 20 25 4.710
  Chloropicrin CCI₃NO₃ 5000 33.55 20 44 44.286
  Phosgene COCl₃ 5000 20.24 20 >77 >47.058
REACTOR Methyloidide₁₃₁ CH₃I - - 2 hours >2 hours -

GAS MASK FILTER LIFETIME:

Breakthrough time of a gas mask filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l/min, which is equivalent to the volume of air per minute used by an average person carrying out medium heavy work. The approximate lifetime (usage time) of a filter may, under normal conditions, calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.

GAS MASK FILTER STORAGE AND MAINTENANCE:

Each NBC-77 SOF gas mask filter is sealed in a plastic bag by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30°C and relative humidity below 80%. Sealed filters tolerate also conditions of -30 to +50°C and RH below 95%. The storage period (month and year) for filters is marked on the filter label. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.

GAS MASK FILTER DISPOSAL:

After use, gas mask filters are considered special refuse. Make sure that they are disposed of according to the filtered substance (gases or particles) in accordance with current waste treatment regulations. If the product is to be disposed of, it should be dismantled from the respirator and disposed of as solid waste. Please see local authority regulations for disposal advice and locations.